Fire Safety Design for Warehouses and Racking Systems

By Van Tam|30/10/2026 08:00

Adding a rack level can create more storage capacity while changing the conditions on which fire protection was designed. Fire safety therefore needs to be coordinated with the layout, inventory and operating model. The presence of a fire suppression system does not mean that every storage arrangement is suitable.

Identify commodities and storage arrangements first

Warehouse planning often starts with floor area, storage positions and picking productivity. Fire protection design also needs information about materials, packaging, storage height and rack arrangements. These inputs should be established early so that architecture, structure and protective systems can be coordinated. Choosing equipment only after the rack layout has been fixed may require the layout to be revised. The inventory assumptions are part of the design brief, rather than details to be supplied after construction.

In its explanation of commodity classifications under NFPA 13, the US National Fire Protection Association, NFPA, describes classification as a basis for selecting suitable sprinkler system design. The management implication is to identify the product together with its packaging and load-supporting materials. A trade name, or the fact that the product itself is metal, does not establish the fire hazard of the complete stored unit. The assessment needs information about the actual load.

23784.jpg

Changing from ordinary boxed goods to products containing substantial amounts of plastics can alter design inputs. Different packaging, additional wrapping or a different storage arrangement also merit review. Commercial teams should supply the design team with a meaningful inventory profile rather than describing the premises simply as a general warehouse. Goods requiring special consideration should be identified separately so that the protection strategy does not depend on an incomplete description of expected operations.

Each storage area should have a recorded operating basis covering commodities, rack type, storage height permitted by the design and relevant limitations. The record needs to be reconcilable with drawings and installed equipment. It gives managers a basis for deciding whether a new consignment fits existing conditions or requires further assessment. Such information should remain available during operation, rather than being treated only as part of the building handover archive.

Coordinate racking with the complete protection strategy

NFPA’s warehouse fire-protection guidance highlights the challenges of multiple-row racks and maintaining necessary flue spaces as storage depth increases. For operators, spaces required by the design are not spare capacity to be filled. Overhanging loads, wrapping or temporary supports can make the actual arrangement differ from the assessed configuration. Layout control therefore concerns the position and form of stored loads as well as the steel rack structure itself.

Rack height, storage height and building height are different parameters. An extra level or a change in package size calls for review of the relationship between goods, sprinklers and obstructions. Additional shelves, signs or structures also need consideration. A system cannot be assumed suitable merely because the sprinkler heads remain in their original positions. Changes below them can alter the conditions the protection arrangement was intended to address.

49518.jpg

In Vietnam, QCVN 06:2022/BXD together with Amendment 1:2023 provides a basis for fire safety of buildings and constructions. The Ministry of Construction published a consolidated document dated 28 September 2026. Warehouse design needs to check applicability, transitional provisions and the specific project records. Fire-hazard classification, escape provisions, fire-spread limitation and firefighting access need coordinated consideration rather than separate decisions made after the storage plan has been finalised.

Racking should not be planned independently of escape routes, fire compartments or access to protective equipment. A forklift aisle does not automatically satisfy every escape-route requirement. Designers need to establish the function of each route and ensure that stored goods do not undermine it. In a multi-tenant warehouse, responsibility for shared areas should be explicit. Each occupier’s local storage decisions can affect conditions that other users depend on.

Hypothetical example: a storage area operates under an established configuration. The business proposes an additional rack level and loads containing more plastics. Both changes need to be assessed together. Adequate rack capacity does not establish that the fire-protection arrangement remains suitable. The revised configuration should be used only after the corresponding technical requirements, documentation and procedures have been established. This example does not prescribe a universal design threshold or a sprinkler specification.

Maintain the design basis throughout operations

Equipment provision also needs checking against the relevant Vietnamese requirements. The Ministry of Public Security issued Circular 103/2025/TT-BCA promulgating QCVN 10:2025/BCA on fire prevention, firefighting and rescue equipment for buildings and constructions, effective from 30 December 2025. The responsible team needs to establish the applicable requirements and transitional arrangements for its case. A standard equipment shopping list cannot establish suitability for every warehouse or alteration.

NFPA publications provide technical references and may form part of the standards selected for a project under the applicable rules. Citing NFPA does not, however, replace the need to identify obligations under Vietnamese technical regulations. Designers should establish the project’s adopted documents and the consistency of the resulting solution. An isolated parameter taken from an overseas publication is not a substitute for assessing the complete design and its application to the building.

56587.jpg

Each capacity-increase proposal should undergo change review before implementation. The review should consider commodities, rack configuration, protective systems and escape conditions. Operating teams should not raise storage limits simply because unused space remains below the roof. Where changes are necessary, the technical solution and corresponding documentation and procedures need to be established before the revised area is used. This makes change control part of capacity planning rather than a response to a completed alteration.

Operational inspections should examine actual conditions, including encroachment on escape routes, obstructed equipment, exceeded storage limits and blocked spaces required by the design. System inspection and maintenance need to follow applicable requirements, with responsibility assigned for tracking findings and corrective work. An old inspection record cannot establish the present condition of equipment after repeated inventory and layout changes. Records are useful when they remain connected to the warehouse as it currently operates.

Lease and supplier arrangements should identify who manages racks, who monitors shared systems and who reports changes in stored goods. The parties should also agree how an impairment of protection will be managed. Rent and storage-position counts should be considered alongside the ability to sustain safe operating conditions. Otherwise, an apparent capacity gain can introduce refurbishment costs or interruptions that were missing from the original commercial comparison.

Warehouse fire safety depends on the compatibility of the building, stored goods and protective systems. Good design needs to be sustained through operational inspection and change management. Clearly recorded storage limits, shared project information and assessment before alterations give the business a stronger basis for improving utilisation while maintaining safe conditions. The objective is a warehouse whose daily use continues to match the conditions on which its protection was designed.

Bài liên quan
  • What rail freight needs to attract more cargo from road transport
    Rail can attract more cargo from roads when shippers can see a benefit across the complete journey, from the dispatch warehouse to the receiving warehouse. Turning the ability to carry large loads into regular orders requires freight trains, terminal yards, connecting trucks and delivery commitments to work together. The service must be dependable enough for businesses to incorporate it into their production and distribution plans.

(0) Bình luận
Nổi bật Tạp chí Vietnam Logistics Review
Đừng bỏ lỡ
Fire Safety Design for Warehouses and Racking Systems
POWERED BY ONECMS - A PRODUCT OF NEKO